SD300 Series VFD for Outdoor Pumps

22-01-2026

SD300 Series VFD for Outdoor Pumps

The SD300 series outdoor pump-specific VFD (Variable Frequency Drive) is designed specifically for complex outdoor working conditions. It features an enhanced algorithm for precise flow and pressure control, a long-life design, and the ability to withstand harsh environments. The lower-end wiring and handle design make installation and transportation convenient. It also supports remote access, with upgraded lightning protection for enhanced safety and peace of mind.

PRODUCT CHARACTERISTICS

Precise control: Algorithm enhancement for precise control

Rich energy-saving function:Adopting energy-saving control technology to ensure e f ficien t and energy-saving operation of the motor

Convenient to install and carry:THE lower end in and out of the line design, installation is hassle-free; intimate carrying handle design, more convenient to carry.

Enhanced lightning protection design:Special enhanced lightning protection circuit, safety is consolidated again

Safety & High Reliability:Safe to use even in harsh environments by adop ting long-li fe design, ins tan taneous blackout countermeasures, and humidityand dust-resistant treatments.

Remote monitoring:Can be accessed from a remote location via a smartphone and is able to automatically adjust the operating status based on realtime data.

SPECIFICATION PARAMETERS

Model
PPower rating

(kW)

Output current

(A))

Input current

(A)

External dimension

(kW)

SD300-4T-3.0G3.07.1 8.6 3.0
SD300-4T-4.0G4.09.010.53.7
SD300-4T-5.5G5.513.617.55.5
SD300-4T-7.5G7.517227.5

DIMENSIONS & CONFIGURATION PARAMETER

vfd-for-outdoor-pumps



Model

External

 dimension

(mm)

Installation

 dimensions

(mm)


Mounting hole

 diameter

(mm)

HDWW1
H1d
SD300-4T-3.0G220
138
130116
206
5
SD300-4T-4.0G
SD300-4T-5.5G270
151
130
117
257
5
SD300-4T-7.5G

TECHNICAL SPECIFICATIONS


                                                                                                                                                            Power input
Rated input voltage400V Voltage Class:Three-phase 380V~440V
Frequency50Hz/60Hz±5%
Voltage range-20% ~ +15%;Voltage out-of-balance rate<3%
Output voltageThree phase:0%~rated input voltage, error < ±3%
                                                                                                           Power outputOutput frequency0 ~ 600.00Hz(Can be changed by parameter)
Overload capacity150% - 60 s
Control modeSVC、V/F control

                                                                                                     Control characteristics

Range of speed regulatio1:200(SVC)
Speed accuracy0.5%(SVC)
Torque control accuracy5%(SVC)
Torque increaseAutomatic torque lifting; Manual torque increased by 0.1-30.0%
Starting torque0.25Hz/150%(SVC)
ACC/DEC time0.0 ~ 30000s
                                                                                                                                                           Basic functionsCarrier frequency0.5kHz ~ 16kHz
Frequency settingDigital setting + control panel 、Communication
Motor start-up methodsStarted from starting frequency 、DC brake start-up、Speed tracking start
Motor stop methodRamp to stop 、Free stop

                                                                                                       Featured functions

Display and concealment of function codes, fan control, multi-function key settings, various main and auxiliary feeds and switching, a variety of Accel/Decel curves curves optional, analogue auto-correction, high-precision torque limitation, V/f separation control, oscillating-frequency control and operation, multigroup fault recording, over-excitation braking, over-voltage stalling, under-voltage stalling, restarting after a power failure, frequency jumping, frequency bounding, free switching of four acceleration and deceleration times, process PID control, simple PLC, parameter recognition, weak magnetism control, etc. control, simple PLC, parameter identification, weak magnetic control, etc.

                                                                                                                                                                                                           Environment
Altitude0~2000m. De-rate 1% for every 100m when the altitude is above 1000 meters
Ambient temperature-10℃ ~50℃ , The rated output current should be derated 1% for every 1℃ when the ambient is 40℃ ~50℃
Relative humidity5~95%, no condensation
VibrationLess than 5.9m/s² (0.6g)
Storage temperature-20℃~ +60℃
                                                                 OthersIP gradeIP54
Cooling methodForced air cooling


Get the latest price? We'll respond as soon as possible(within 12 hours)