The SG600 series solar pump inverters is a low voltage pumps inverter of 0.3 to 400KW above rating designed to operate with energy drawn from solar panel or photovoltaic cells (PV).
The inverters is customized to operate in dual supply mode (Ac and DC), so the grid connected supply is used in the absence of energy from PV cells. This drive functions with the latest in technology maximum power point tracking (MPPT) algorithm to derive maximum power from the PV cells at any instant.

SG600 Solar pumps inverter MPPT solar pump controller:

solar pump inverter




SG600 solar pump inverter features:

The SG600 series solar pump inverter is a low voltage AC drive of 0.3 to 400KW above rating designed to operate with energy drawn from solar panel or photovoltaic cells (PV).

The inverter is customized to operate in dual supply mode (AC and DC), so the grid connected supply is used in the absence of energy from PV cells. This inverters functions with the latest in technology maximum power point tracking (MPPT) algorithm to derive maximum power from the PV cells at any instant.

1. Maximum power point tracking (MPPT) with fast response speed and stable operation efficiency > 99.6%;

2. High speed running when sunlight radiation is good, frequency reduce fast when sunlight is become weak, stop running when output frequency lower lower limit frequency setting.

3. Suits for most 3 phase AC pumps and AC PMSM high efficiency pumps.

4. The working voltage of solar panel can set by manual or MPPT automatically tracking

5. Compatible with dual power input, AC grid and DC power supply input.

6. Built in automatic sleep-wake up function, start by timer is option.

7. Dry run (under load ) protection

8. Motor maximum current protection

9. Low input power protection

10. Lowest stop frequency protection

11. The PQ (power/flow) performance curve enables calculating the flow output from the pump

12. Digital control for fully automatic operation, data storage and protective functions

13. Intelligent power module (IPM) for the main circuit

14. LED display operating panel and support remote control

15. Low water probe sensor, and water level control function

16. Strong lightning protection

17. Easy operation and CVT auto detection function

18. GPRS function is option for remote start and stop, remote parameters setting.


 Solar pump inverter models and specification:

N

Models

Rate current

Output voltage ( 3PH VAC)

Applicable for pumps

MPPT voltage (VDC)

Mini type 2S series : 90/150 to 450 VDC or 220VAC input,Vmp 310V, Voc 380V

1

SG600-0K7GB-2S-M

3.8A

0-220VAC

0.75KW

260 to 375

2

SG600-1K5GB-2S-M

7A

0-220VAC

1.5KW

260 to 375

3

SG600-2K2GB-2S-M

10A

0-220VAC

2.2KW

260 to 375

4

SG600-4K0GB-2S

17A

0-220VAC

4.0KW

260 to 375

General type: 4T, 250/350 to 800 VDC or 380VAC input, Vmp520, Voc650

1

SG600-0K7GB-4T

2.3A

0-380V

0.75KW

486 to 750

2

SG600-1K5GB-4T

3.8A

0-380V

1.5KW

486 to 750

3

SG600-2K2GB-4T

5.1A

0-380V

2.2KW

486 to 750

4

SG600-4K0GB-4T

10A

0-380V

4.0KW

486 to 750

5

SG600-5K5GB-4T

13A

0-380V

5.5KW

486 to 750

6

SG600-7K5GB-4T

17A

0-380V

7.5KW

486 to 750

7

SG600-011GB-4T

25A

0-380V

11KW

486 to 750

8

SG600-015GB-4T

32A

0-380V

15KW

486 to 750

9

SG600-018GB-4T

37A

0-380V

18KW

486 to 750

10

SG600-022GB-4T

45A

0-380V

22KW

486 to 750

11

SG600-030G-4T

60A

0-380V

30KW

486 to 750

12

SG600-037G-4T

75A

0-380V

37KW

486 to 750

13

SG600-045G-4T

91A

0-380V

45KW

486 to 750

14

SG600-055G-4T

110A

0-380V

55KW

486 to 750

15

SG600-075G-4T

150A

0-380V

75KW

486 to 750

16

SG600-090G-4T

180A

0-380V

90KW

486 to 750

17

SG600-110G-4T

220A

0-380V

110KW

486 to 750

18

SG600-132G-4T

260A

0-380V

132KW

486 to 750

19

SG600-160G-4T

320A

0-380V

160KW

486 to 750

20

SG600-185G-4T

377A

0-380V

185KW

486 to 750

21

SG600-200G-4T

426A

0-380V

200KW

486 to 750

22

SG600-220G-4T

465A

0-380V

220KW

486 to 750

23

SG600-250G-4T

465A

0-380V

250KW

486 to 750

24

SG600-280G-4T

520A

0-380V

280KW

486 to 750

25

SG600-315G-4T

585A

0-380V

315KW

486 to 750

26

SG600-355G-4T

650A

0-380V

355KW

486 to 750

27

SG600-400G-4T

725A

0-380V

400KW

486 to 750


Solar pump inverter technical specification:

Solar pump inverter specification when PE-00=1&2

Recommended MPPT voltage range

Vmp 131 to 350 VDC for 1s 3 phase 110VAC pumps

Vmp 260 to 355VDC for 2S 3 phase 220VAc pumps

Vmp 486 to 650 VDC for 4T 3 phase 380VAc pums

Recommended input Voc and Vmpp voltage

Voc 180(VDC), Vmpp 155(VDC) for 1S model or 110V AC pumps

Voc 380(VDC), Vmpp 310(VDC) for 2S model or 220V AC pumps

Voc 650(VDC), Vmpp 520(VDC) for 4T model or 380V AC pumps

Voc 820(VDC), Vmpp 676(VDC) for 5T model or 480V AC pumps

Motor type

Control for permanent magnet synchronous motor and asynchronous motor pumps.

Rated output voltage

1/3-Phase,110V/160V/220V. 3-phase, 220V/380V/460V

Output frequency range

0~maximum frequency 600Hz.

MPPT efficiency

Above 99.6%,

Ambient temperature range

G-type for submersible pumps, 150% rated current for 60s, 180% rated current for 2s .

P type for general pumps, 120% rated current for 60s, 150% rated current for 2s

Solar pump control special performance

MPPT ( maximum power point tracking), CVT (constant voltage tracking), auto/manual operation, dry run protection, low stop frequency protection, minimum power input, motor maximum current protection, flow calculating, energy generated calculating and water tank level detected

Protection function

Phase loss protection, phase short circuit protection, ground to phase circuit protection , input and output short circuit protection. Stall protection, lightning protection

Protection degree

IP20, Air force cooling

Running mode

MPPT or CVT

Altitude

Below 1000m; above 1000m, derated 1% for every additional 100m.

Enhanced version of AC drive

CE, Design based on vector control motor AC drive, more specification please refer to S600 or S600 vector control drive operation manual